Output Commands
Copyright © Itech Electronic Co., Ltd. 27
*RST value
the stepping resolution of voltage of this unit.
Query order
VOLT:STEP?
Return parameters
<NR2>
VOLT:TRIG{<volts>|MINimum|MAXimum}
This order is used to set a voltage to be triggered. At first, this voltage value is
saved and only when receiving a trigger signal will the power supply output with
this voltage value. Sending order VOLTage will not affect the setting value in
this order. Sending query order, unit will return the previous setting value. If
customer does not utilize order VOLT:TRIG at the beginning, then the return
parameters will be the value you set with order CURRent. CURR:TRIG? MAX
or CURR:TRIG? MIN orders will let you know the max and min voltage you can
set.
Order syntax
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] <NRf>
Parameters
MIN to MAX
Unit
V
Query syntax
VOLT:TRIG? [MINimum|MAXimum]
Return parameters
<NR2>
VOLT:PROTection {<volts>|MINimum|MAXimum}
This order is used to set the upper limit of over voltage protection point. If the
output voltage value is higher than the upper limit of OVP, then we can assume
that internal parts has been shorted. Query state register ”OV” bit has been set.
When power supply is protected, then we can through order VOLT:PROT:CLE
to clear the OVP state.
Order syntax
[SOURce:]VOLTage:PROTection[:LEVel] <NRf>
Parameters
MIN to MAX