IT7300User Manual
User Manual
24
1Hz at 100-500Hz
Accuracy
0.1HZ
Phase
angle
Range
0-360°
Resolution
0.1°
Accuracy
±1°(45-65Hz)
Measuring Range
Voltage
Range
0-500V
Resolution
0.1V
Accuracy
±(0.2% + 1.2V)
Current
(rms)
Range
L:120.0mA/ M:1.200A/ H:3.00A
Resolution
L:0.1mA/ M:1mA/ H:10 mA
Accuracy
L: ±(0.2%+0.6mA)/ M: ±(0.2%+6mA)/ H: ±(0.2%+40mA)
Current
(peak)
Range
0-12A
Resolution
0.01A
Accuracy
±(1% + 360mA)
Power
Range
L:0.01W/ M:0.1W/ H:1W
Accuracy
L: ±(0.2%+0.2W) (47HZ-65HZ)/ M: ±(0.2%+2W) (47HZ-65HZ)
/ H: ±(0.2%+6W) (47HZ-65HZ)
Specification
Memory
10 memories
Sync Output Signal
Output Signal 5V, BNC type
Interface
LAN, USB, RS232,GPIB
Operation Environment
0-40℃/20-80%RH
Dimension
439mmW×131.4mmH×535.7mmD
Weight
40kg
Model IT7324H
AC input
Input
Phase 1
Voltage 220Vac/110Vac±10%
Current 30A(220Vac) or 60A(110Vac)
Frequency 47-63Hz
Power factor 0.7(typical)
AC output
AC output
Max.Power
1500VA
Max Current(rms)
6A(0-250V)
3A(0-500V)
Max Current(peak)
24A (0-250V)
12A(0-500V)
Phase
1Φ/3W
Total Harmonic
Distortion(T.H.D)
≤1% at 45-500Hz (Resistive Load)
Crest Factor
≤4
Line Regulation
0.1% max for a ±10% line change
Load Regulation
≤0.5%FS (Resistive Load)
Response Time
<100uS
Setting
Voltage
Range
0-500V, 250/500V Auto
Resolution
0.1V