Load Commands
Copyright © Itech Electronic Co., Ltd. 20
Chapter3 Load Commands
INPut
This command indicates whether electronic load is enabled.
Command syntax:
[SOURce:]INPut[:STATe] <bool>
Parameter:
0|1|OFF|ON
Reset value:
0
Query Syntax:
[SOURce:]INPut[:STATe]?
Returned value:
0|1
INPut:REAL?
This command indicates whether the electronic load is really applied to the
loop.
Command syntax:
[SOURce:]INPut:REAL[:STATe]?
Returned value:
0|1
FUNCtion
This command is used to read the operating mode of electronic load.
Command syntax:
[SOURce:]FUNCtion <CURRent|RESistance|VOLTage|POWer|SHORt >
Parameter:
CURRent|RESistance|VOLTage|POWer|SHORt