Load Commands
Copyright © Itech Electronic Co., Ltd. 32
Reset value:
SLOW
Query Syntax:
[SOURce:]RATE:DCCV?
Returned value:
SLOW|HIGH
RATE:CC
This command is used to set the load rate in CC mode under AC/DC working
mode.
Command syntax:
[SOURce:]RATE:CC <SLOW|HIGH>
Parameter:
SLOW|HIGH
Query Syntax:
[SOURce:]RATE:CC?
Returned value:
SLOW|HIGH
WAVE:TRIGger:VOLTage[:LEVel]
This command is used to set the voltage trigger level.
Command syntax:
WAVE:TRIGger:VOLTage[:LEVel]
Parameter
<NRf>
Unit
V
Query Syntax:
WAVE:TRIGger:VOLTage[:LEVel]?