Parameter:
MINimum|MAXimum|DEFault or NRf
Unit:
w
Reset value:
MINimum
Query Syntax:
[SOURce:]POWer[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returned value:
<NR3>
[SOURce:]POWer:MAXimum[:LEVel]
This command is used to set the maximum power value.
Command syntax:
[SOURce:]POWer:MAXimum[:LEVel]
Parameter:
MINimum|MAXimum|DEFault or NRf
Unit
W
Reset value
MAXimum
Query Syntax:
[SOURce:]POWer:MAXimum[:LEVel]? [MINimum|MAXimum]
Returned value:
NR3
POWer:PROTection
This command is used to set the power protection level of electronic load.
Command syntax:
[SOURce:]POWer:PROTection[:LEVel] <NRf+>