Copyright © Itech Electronic Co., Ltd. 27
Parameter:
MINimum|MAXimum|DEFault or NRf
Unit:
w
Reset value:
MAXimum
Query Syntax:
[SOURce:]POWer:PROTection[:LEVel]? [MINimum|MAXimum]
Returned value:
NR3
POWer:PROTection:DELay
This command is used to set power protection delay of electronic load.
Command syntax:
[SOURce:]POWer:PROTection:DELay <NRf+>
Parameter:
MINimum|MAXimum|DEF or NR3
Unit:
s
Reset value:
MAXimum
Query Syntax:
[SOURce:]POWer:PROTection:DELay? [MINimum|MAXimum]
Returned value:
<NR3>
POWer:PROTection:STATe
This command is used to set power protection of electronic load.
Command syntax:
[SOURce:]POWer:PROTection:STATe <bool>