EasyManua.ls Logo

ITech IT8600 Series

ITech IT8600 Series
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Calibration Commands
Copyright © Itech Electronic Co., Ltd. 57
Parameter:
P1|P2|P3|P4
CALibrate:RESistance
This command is used to calibrate the measurement resistance point.
Command syntax:
CALibrate:RESistance[:LEVel] <NRf> ,<NRf>
Parameter:
Voltage< external reading >, Current< external reading >
Unit:
V,A
CALibrate:RESistance:BIAS:POINt
This command is used to calibrate the bias point of resistance.
Command syntax:
CALibrate:RESistance:BIAS:POINt <point>
Parameter:
P1|P2|P3|P4
Unit:
None
CALibrate:RESistance:BIAS
This command is used to calibrate the bias level of resistance.
Command syntax:
CALibrate:RESistance:BIAS[:LEVel] <NRf>,<NRf>
Parameter:
Voltage< external reading >, Current< external reading >
Unit:
V,A
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for ITech IT8600 Series

Related product manuals