System Commands
Copyright © Itech Electronic Co., Ltd. 47
Returned value:
<NR2>
SYSTem:ERRor?
This command is used to query the error information.
Command syntax:
SYSTem:ERRor?
Parameter:
None
SYSTem:REMote
This command is used to switch the AC load to remote control mode. In this
mode, except Local button (pressing Local button to back to local mode), other
keys are locked.
Command syntax:
SYSTem:REMote
Parameter:
None
Query Syntax:
None
SYSTem:LOCal
This command is used to switch the AC load to local operation mode. After this
command is executed, all the keys on the panel are available.
Command syntax:
SYSTem:LOCal
Parameter:
None
Query Syntax:
None