Calibration Commands 
  Copyright © Itech Electronic Co., Ltd.  54 
Parameter: 
None 
For example: CAL:INIT 
Relevant Command: 
CAL:STAT   CAL:INIT 
CALibrate:SAVe 
This command is used to save calibration coefficients in nonvolatile memory. 
Command syntax: 
CALibrate[:USER]:SAVe 
Parameter: 
None 
CALibrate:VOLTage:POINt 
This command can only be used in calibration mode. It is used to set the 
calibration points of constant voltage mode. P1, P2 is used in low voltage meter 
range, P3, P4 is used in high voltage meter range. It can use calibrate voltage 
source and voltage meter. 
Command syntax: 
CALibrate:VOLTage:POINt <point> 
Parameter: 
P1 | P2 | P3 | P4 
Example:CAL:VOLT:POIN P2 
Relevant Command: 
CAL:STAT   CAL:SAV 
CALibrate:VOLTage 
This command is only used in calibration mode. It enters a calibration voltage 
value that you obtain by reading an external meter. You must first select a 
calibration level (with CALibrate:VOLTage:POINt) for the value being entered. 
These constants are not stored in nonvolatile memory until they are saved with 
CALibrate:SAVE. 
Command syntax: 
CALibrate:VOLTage[:LEVel] <NRf>