Page 5-28 ITW Dynatec
Revised 1/16 V6 DCL Touch Screen Controller for Dynamelt M & D ASUs
Fieldbus Setup Screen
To go to this screen, press the Fieldbus Settings button on the Settings Screen.
When communicating to a parent machine which utilizes profibus or EtherNet IP, the unit must
have a Fieldbus Address to identify it. When there are additional units in a system, each unit must
have its own unique Fieldbus Address.
Item Description
1
Fieldbus Address
Touch the input box and a numeric entry keypad will appear. Enter the Fieldbus Address of the
unit. Confirm by pressing OK.
After programming the Fieldbus Address, the system must be re-started. To re-start the
system with changed parameters:
1. Press OK to accept changes.
2. Wait at least one minute.
3. Switch unit Off via the main switch.
4. Switch unit On via the main switch.
2 Press the OK button to confirm your entered values and return to the previous screen.
3 Press the ESC button to discard any non-confirmed values and return to the previous screen.
1
2
3