Page 2-2 Description
Revised 10/14
ITW Dynatec
D15/D25/D45 V6 DC L ASU Manual #20-63
Specifications
Environmental
Storage/ shipping temperature -40 Cto70C(-40 F to 158F).............................
Ambient service temperature -7 Cto50C(20 F to 122F)...............................
Noise emission < 70 dbA (at 1 meter).................................................
Physical
Dimensions see dimensional layouts on following pages..................................
Number of heads/ hoses 2, 4 heads/ hoses..............................................
Number of hopper temperature zones 1 (add 1 or 2 for optional drop-in grids).................
Number of pumps 1 or 2, single or dual...............................................
Gear pumps (standard) 1.5cc/ rev, 3.2cc/ rev or 4.5cc/ rev..................................
Enclosure rectangular steel, dust and splatter resistant....................................
Hose connections universal 15-pin Amphenol connectors at ASU,...........................
wrench-secured fluid fittings (#6 JIC)
Hopper (tank) capacity D15 = 15 kg/ 33 lb..............................................
D25 = 25 kg/ 55 lb
D45 = 45 kg/ 100 lb
Hopper construction welded aluminum, cast-in heaters, TFE Teflon coated...................
Filtration hopper bottom screen and large pleated pump outlet filters.........................
Weight, empty D15 = 155 kg/ 342 lb..................................................
D25 = 155 kg/ 342 lb.
D45 = 182 kg/ 401 lb.
Fluid outputs 1 to 4 metered, 6 un-metered.............................................
Optional drop-in grids D25 = 1 available...............................................
D45 = 1 or 2 available
Adhesive form accepts most forms...................................................
Electrical
Service Requirements ........................ 200-240 VAC/ 60 A*/ 3p/ 50-60 Hz (Delta)
380-400 VAC/ 30 A*/ 3p/ 50-60 Hz (Wye, Y)
Power consumption, system maximum 26,700 watts......................................
Power consumption, hopper 2,500 watts..............................................
Hopper heater type cast-in tubular....................................................
Temperature control microprocessor-based proportional integral d erivative (PID)...............
Temperature sensors 100 Ohm Platinum RTD...........................................
Electrical connectors durable, latching connectors.......................................
Motor one or two 1/4 hp, alternating current motor, direct drive, horizontal orientation..........
Maximum wattage available for each hose or head 2400 watts..............................
Maximum wattage available for each auxiliary 2400 watts.................................
External electrical connectors 2 (4) hose, 2 (4) head, 2 (4) aux..............................
* actual circuit breaker current depends on ASU configuration