LCD Programming Page 5-3
Revised 10/14
tatus Line
The status line is the top line of the display. It always lists the System Status, the Time‐of‐Day
and the Pump Status. It can also include the status of the Keypad (if locked) and the 7‐Day
Scheduler (if active). An example of an Overview Screen status line is seen below.
System Status
The status of the “system”, ie. the ASU (melter) and its hoses and applicators, is listed as one of
the following:
Pump Status
The status of the adhesive pump is indicated as follows:
Time 7‐Day Scheduler is active Pump Status
System Status Keypad is locked
HEAT‐UP No faults present, zones are heating but haven't reached their setpoint window
READY No faults present and all zones are within the setpoint window
ALARM At least one zone is outside the setpoint window (over or under temp)
STANDBY The system is in standby mode
OVER‐TEMP The hopper is in over temperature condition, all power circuits are shut off
FAULT A t emperature zone has a fault and all power circuits are shut off or the motor drive has faulted
HOPPER EMPTY Adhesive in the hopper is low and must be replenished
Temperature Zone Symbols
Each temperature zone is represented by a symbol on the display, as follows:
PUMPS Pump has start signal and is actually running (seen on Overview Screen, upper right corner)
HOLD Pump is in Run mode (auto or manual) but a low temperature condition prevents it from
running (seen on Overview Screen, upper right corner)
STOP Pump is in Stop mode (seen on Pump Screen)
ASU's
Hopper
(up to 3)
(not used in the
DSeries
configuration)
Hoses
(up to 12)
Applicator Heads
(up to 12)
ASU's
Premelt
(Drop‐in)
Grids
(up to 6)
Auxiliary Zones
(up to 12)
AUX-ZONE