ITW Dynatec Programming Page 5-29
V6 DCL Touch Screen Controller for Dynamelt M & D ASUs Revised 1/16
General Settings Screen
To go to this screen, press the General Settings button on the Settings Screen.
This screen allows you to set the parameters shown across the screen’s top line (Item #1, shown
below).
Select a desired parameter (Temperature, Standby, Level Control, Pressure Calibration or
Customer Zone Names) by pressing its tab or by pressing the arrows at the bottom of the screen.
Temperature Settings
Item Description
1
Parameter Selection tabs
The Temperature Settings tab has been selected.
2
• The Pump Enable Temperature is a low-limit value (e.g. 100°C / 212°F) which protects the
pump, pump shaft, motor and motor control module by preventing the pump from turning on
until a minimum adhesive temperature is achieved. Caution should be taken to avoid setting
this value too low because attempting to rotate the pump when the adhesive inside it is not
molten will result in damage to the pump and, possibly, to the pump motor. The Pump
Enable Temperature is independent from the temperature setpoints. The programmable
range is 10-200 °C (50- 400°F).
• Touch the input box and a numeric entry keypad will appear. Enter your desired Pump
Enable Temperature value and confirm by pressing OK.