ITW Dynatec
D15/D25/D45 V6 DC L ASU Manual #20-63
Installation Page 3-1
Revised 10/14
Chapter 3
INSTALLATION
Placing the ASU
The D15/D25/D45 SERIES ASUs can stand alone on flat surfaces. Access is needed for the main
electrical power and the serial communication connections to come in from below the unit and to
connect to the V6 Base Module (which is inside the panel box). There is a cutout in the ASU’s base
plate, directly below the pump shaft, which allows adhesive to drain.
The ASU’s hinged hopper lid may be rotated 90 degrees in any direction, so that it can be set up to
open in the most convenient direction.
For installation dimensions, see illustration on page 2-4.
D15/D25 Adhesive Supply Unit (ASU)
DynaControl Controller
Main On/Off
Disconnect Switch
Hopper Cover
Hopper Lid
Hopper Access Cover
Base Plate
Front Door Lock
Latch (1 of 4)
Key Lock
Panel Box Cabinet
DANGER INSTALL ON FLAT SURFACE
Typical equipment configuration includes wheels and brakes, which should be
engaged whenever the equipment is not being transported. DO NOT install
equipment on a sloped surface. Transportation of equipment over a sloped surface
presents an increased risk of injury in the event of uncontrolled rolling.