LCD Programming Page 5-25
Revised 10/14
Global Setpoints (P4)
Setpoint programming may be simplified by programming Global Setpoints. With this paramet
er, the user programs a hopper setpoint and the controller configures all of the other zones.
However, to do so, it must be appropriate for all your hoses to be programmed to one setpoint,
and for all your applicator heads to be programmed to one setpoint.
After turning the Input Wheel to select the Global Setpoints parameter, press the Enter Knob to
turn Global Setpoints On/Off.
Then press F3 to open the Global Setpoints menu.
On the Global Setpoints menu, you set up simple mathematical relationships (increases)
between the hopper setpoint and the s etpoints of the hoses and applicator heads. Pressing the
Input Knob increases the temperature of the hose (or head) by 5 degrees, or, if you press again,
by 10 degrees (press again for 15 degrees, and press again fo r 20 degrees). Once setup, all of the
hoses will increase over the hopper setpoint by the same amount (0, 5, 10, 15 or 20 degrees)
and likewise, all of the heads will increase over the hopper setpoint by the same amount as you
program here.
Once Global Setpoints are set, you simply program the hopper (as described on page 56) and
your hoses and heads will automatic ally be programmed to the increases you specified on the
Global Setpoints menu.
For example: If you setup a Global Setpoint increase of 10 degrees for Hoses and 15 degrees for
Heads, and you program your Hopper setpoint to 290 degrees, then the controller will automat
ically progra m all of the hoses to 300 degrees and all of the heads to 305 degrees.
When Global Setpoints are turned On and a temperature setpoint is changed, the display will
not show the selected zone's name. Instead it will display GLOBAL SET:.
You can still turn individual zones Off and On while using Global Setpoints.