ITW Dynatec Programming Page 5-1
V6 DCL Touch Screen Controller for Dynamelt M & D ASUs Revised 1/16
Chapter 5
DYNACONTROL V6 TOUCH PANEL for DYNAMELT M & D ASUs
Version 01.2016
Setup Your System's Parameters
Program the controller parameters to meet the specific temperature requirements of your
production
.
Setpoints for each temperature zone must be programmed as well as a standby
temperature, pump enable temperature, temperature alarm window and temperature alarm
hysteresis.
Choices must be made for recipe (program) selection, pump (or motor) conditions and heating
priority
.
If desired, temperature zone offsets and/ or a temperature zone enable may be selected.
Numeric Entry Keypad
Use the numeric entry keypad to enter or change numeric parameters (values).
In the top window, the temperature zone name and its setpoint value will be displayed.
This is a typical example of the numeric entry keypad:
Item Description
1
By pressing the OK button the entered values will be confirmed and stored in the controller.
The numeric entry keypad closes and you will return to the previous screen.
2
By pressing the ESC button any entered but not yet confirmed values will be discarded and
you will return to the previous screen.
Delete
button
1
2