Programming the Zone Names
NOTE: This feature cannot accommodate Chinese language characters.
After selecting the Customer Zone Names parameter and pressing the Enter Knob to display YES,
press F3 (Change Text) to begin programming.
1. Turn the Input Wheel to select desired temperature zone (refer to corresponding RTD). The
selected zone is highlighted.
2. Press the Input Knob to confirm zone.
3. Turn the Input Wheel to select the character to be reprogrammed.
4. Press the Input Knob to confirm selection. The cursor highlights the selected characte r.
5. Turn the Input Knob to select the new cha r acter.
6. Press the Input Knob to confirm the new character.
7. Repeat steps 3 through 6 to spell desired zone name.
8. Press the Return button to select another zone to program. Repea t steps 1 through 6
for each zone desired.
9. Press Return again when all te mperature zone name programming is completed.
Logbook/ Fault History (P4)
The Logbook provides a readonly history of the last 65 (maximum) controller faults and events.
Controller fa ults include sensor or temperature errors or motor faults. Examples of an event in
clude switching the ASU on/off or System Ready. The most recent event is recorded at the top
of the list (No. 1).
Day, Ti me and Event are listed for each item in the Logbook. This information can be valuable
when troubleshooting controller problems.
After turning the Input Wheel to select the Logbook parameter, press the Enter Knob to display
the Logbook. Turn the Input Wheel to scroll through the list.
#1 is most recent entry