Page 5- 18 LCD Programming
Revised 10/14
ITW Dynatec
D SERIES V6 DCL ASU Manuals
Setpoint Limitation (P2)
This parameter sets the maximum temperature zone setpoint. The setpoint limitation is useful
for an adhesive with a low melt temperature. In this case, the maximum selectable setpoint
could be lowered in order to avoid overheating the adhesive.
After turning the Input Wheel to select the Setpoint Limitation parameter, press the Enter Knob
and then turn the Input Wheel to select your desired setpoint limitation value. Confirm your
choice by pressing the Enter Knob.
Hi/Lo Tolerance (P2)
A high and low temperature tolerance can be set for the temperature zones. During operation,
these tolerances activate the error alarms which alert the operator to overtemp and un
dertemp conditions.
The hi/ lo tolerance is a range (+ and ) from the setpoint. Thus a setpoint of 150C which has
been programmed with a 10 hi/ lo tolerance will activate an undertemp alarm when the zone's
temperature falls below 140C and will activate an overtemp alarm when the zone's temperat
urerisesabove160. When this zone's temperature is within the tolerances (140 and 160), it
is considered “Ready”.
When programming, only one value is chosen. This value applies to all temperature zones and is
both the hi gh and low tolerance.
After turning the Input Wheel to select the Hi/Lo Tolerance parameter, press the Enter Knob and
then turn the Input Wheel to select your desired tolerance value. Confirm your choice by press
ing the Enter Knob.
Standby Configuration (P2)
There are four ways to activate standby mode:
1. Manually, at the Main Menu's F2,
2. Automatically, via the 7Day Scheduler,
3. Remotely, via an external contact (program as described below), or
4. Automatically, after a pump stop (program as described below).
Standby Configuration allows you to select #3 or #4 and program other standby parameters.
Program a standby time delay
Program a standby temperature difference
ToggletochooseAfterExternal
Contact or After Pump Stop
Program a sleep mode after standby time delay