ITW Dynatec
D SERIES V6 DCL ASU Manuals
Controller Setup Page 4-3
Revised 10/14
LCD Error Indication Alarms
The following illustration shows the display that will be activated when one or more error indica-
tion alarm conditions occur. The conditions that will trigger an alarm are:
When a hopper, hose or head has exceeded its selected over-temperature setpoint, which is the
setpoint plus its Hi/Lo alarm setting.
When a hopper, hose or head sensor has an open circuit.
When an alarm condition occurs, the current display will be interrupted only if a sensor failure
occurs. If more than one alarm condition occurs simultaneously, all alarm conditions will be dis-
played sequentially.
Temperature Zone Enable
The temperature zone enable allows the operator to disable unused temperature zones in such a
way that they do not appear on the controller’s display and heating is switched OFF.
V6 Base Module
The main control module of the system. It controls and communicates with the temperature con-
trol module, the operator interface and all auxiliary modules and I/O devices.
V6 Temperature Module
Monitors temperature signals from all heated zones and provides control signals to the Power and
Auxiliary PCBs (modules).
DynaControl V6 LCD Display During Normal Operating Mode
Zone
Symbols
Zone
Bar‐Graph
Status
Line
Keypad Status
7‐Day Scheduler
Status
Time of Day
System Status Pump Status
Pump
Information:
Pressure,
Speed, Mode
F1, F2, F3, F4, F5:
Toggle “On/Off”
selected functions
320 PSI