Page 5- 22 LCD Programming
Revised 10/14
ITW Dynatec
D SERIES V6 DCL ASU Manuals
Customer Zone Names (P4)
With this configuration parameter, the user may personalize the names of the temperature
zones with names that are more descriptive for his application. That is, instead of the factoryset
zone names of Z01, Z02, Z03, etc., the customer may prefer temperature zone names such as
TANK,“HEAD1,“FILTERBLOCK,“SUPPLYHOSE LEFT”, etc.
After turni ng the Input Wheel to select the Customer Zone Names parameter, press the Enter
Knob to display YES. To enter programming mode, press F3 (Change Text).
Now, by turning the Input Wheel, you can scroll through the zones and see their current zone
names (or numbers). These names can be reprogrammed one at a time. Each new name may
consist of two lines, with a maximum of 12 characters in each line. Note: the factoryset numeric
“names“ correspond to RTD inputs.
Customer Zone Name Programming Screen
Programming keys
Using F2, F3, F4 & F5 Programming Keys
F5 = press to Clear the entire zone name.
F2 = press to select upper or lower case le tters, to select numbers or to select special characters.
F3 & F4 = press to Copy (F4) and Paste (F3) the name of one zone into another.
Programmed name
Zone indicators
(see below)
Selected zone (Z6)
Selected character (E)
with cursor below (^) it
Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16
This line = 12 characters This line = 11 characters
“Supply Hose Left Side” = Zone #6 (highlighted zone indicator)
Zone indicators
Zone numbers