ITW Dynatec Programming Page 5-43
V6 DCL Touch Screen Controller for Dynamelt M & D ASUs Revised 1/16
Item Description
2
Programming
• Select a timer for programming by pressing Timer 1, Timer 2 or Timer 3.
• Select either System On/Off or Standby On/Off.
• Using the up and down arrows, set the start time hour and minute. The scheduler will
automatically turn On the unit at this time.
• Using the up and down arrows, set the stop time hour and minute. The scheduler will
automatically turn Off the unit at this time.
• Using the up and down arrows, set the cycle. The scheduler will automatically turn the unit
On and Off on these days.
• By pressing the Enable Scheduler button, the programmed parameters will be confirmed
and the selected timer is activated.
To change a timer program, first select the desired timer. Then press the Disable Scheduler
button. Now the selected timer can be re-programmed with new parameters as described
above.
The „clock“
icon appears in the status line on main screen if a timer is activated and
disappears if the timer is deactivated.
3
BACK Button
Press to return to the previous screen.
4
Turn System Off
Press System Off to turn the system Off. Refer to "Control switch On/Off and Standby".
5
Current Date & Time
Display of the current date and time as programmed into the controller.
The display on the
right shows Timer 2
programmed and
activated for
Standby On/Off with
a Start time of
12:00, a Stop time
of 13:00 and a Cycle
of Mon-Fri.