ITW Dynatec
D SERIES V6 DCL ASU Manuals
Troubleshooting Page 7-21
Revised 10/14
Problem Possible Cause
(Optional) Drop-In Grid 1. Sensor cable has become
Sensor Open unplugged from the Tem-
perature Module.
2. Drop-in Grid sensor
inoperative.
(Optional) Drop-in Grid 1. Short-circuit caused by
Sensor Short debris where sensor plugs
into the Temperature
Module.
2. Pinched sensor lead wire.
3. Drop-in Grid sensor
inoperative.
Solution
1. Verify that grid sensor cable is
properly connected at X3 (or X2) on the
Temperature Module.
2. Replace grid sensor if resistance
does not comply with resistance table.
1. Verify that sensor plug is clean and
correctly connected at X3 (or X2) on
the Temperature Module.
2. Visually inspect sensor lead wire for
break, kink, damage, etc. If no obvious
damage, use an ohmmeter t o measure
continuity from the sensor lead to the
plug at X3 (or X2) on the Temperature
Module. Repair or replace any damaged
wire.
3. Replace grid sensor if resistance does
not comply with resistance table.