Page 3-4 Installation
Revised 10/14
ITW Dynatec
D15/D25/D45 V6 D CL ASU Manual #20- 63
DynaControl V6 Power Module
Verify Voltage Configuration Connector
according to your voltage :
240V Three phase = Violet
400V Three phase = Yellow
Connect to Main Power ON/OFF Switch
according to your voltage (see chart on
next page).
3. A voltage configuration connector (plug), appropriate for your order, has been installed in your
ASU. Before proceeding, verify that this plug is correct for your operating voltage.
The voltage configuration connector is installed on t he DynaControl V6 Power Module (see m odule
illustration below). For location of the module, see illustration on page 3-7.
There are two different voltage configuration connectors available:
240V Three p hase = P/N 115725 (Violet)
400V Three phase = P/N 115726 (Yellow)
For reference, the schematics of each voltage configuration connector is printed on the next page.
CAUTION: Using the incorrect power configuration connector may cause serious
damage to the unit.