Page 5-6 ITW Dynatec
Revised 1/16 V6 DCL Touch Screen Controller for Dynamelt M & D ASUs
Item Description
3
• The actual values of the temperature zones are displayed in columns under the icons. Zone
status is indicated by color: the zone field is colored green when the zone reaches setpoint,
yellow while the zone is heating up, grey it it has been temporarily switched off and red if in
alarm.
• When all zones have reached their setpoint values, READY will be displayed in the status
line. If zones are still heating up and have not yet reached their setpoint values, NOT
READY will be displayed in the status line.
• If six or fewer zones in any column are activated, the temperature status of each zone is
shown by a bar‐graph indicating if the temperature zone is inside its setpoint window
(green) or outside (yellow). The bar-graph indication disappears if more than six zones are
4
The appropriate actual values (pump rpm, pressures) are displayed under the icons.
Primary pressure: If the system is equipped with a (primary) pressure sensor, the
appropriate primary pressure transducer input will be displayed with number 1
.
The primary pressure input can be controlled via the Pressure Set Point in Pump Control/
Pressure Control Screen.
Secondary pressure: If a second pressure sensor is equipped (usually in
combination with dual pump outlets), the appropriate pressure transducer input will be
displayed with number 2
.
The secondary pressure input is just a readout function.
The display alternates between primary pressure 1 and secondary pressure 2.
5
If an optional digital level sensor is built-in, Hopper Empty status will be
indicated when adhesive drops below the level sensor.
If an optional analog probe used the status bar will display the adhesive level
along with a percentage of hopper volume.
6
By pressing Set, values may be displayed and edited. The display will automatically return to
actual values after about 15 seconds, if there is no display activity.
7
Pumps Button
Press to go to the Pump Overview screen.
8
Acknowledge Button
Press to acknowledge an error or alarm.
9
Control Button
Press to go to the Control screen.
10
Systems Button
Press to go to the Systems screen, if several systems are controlled by the HMI.
11
Settings Button
Press to go to the Settings screen.