Zinc anodes corrosion inspection
Proceed with engine not running and at low temperature:
Place the necessary basins in order to avoid water to spill off during
removal of anodes.
Unscrew and remove anodes (se relevant location in ENGINE
TECHNICAL DATA).
Make sure corrosion does not involve over 50 % of zinc volume.
Otherwise replace them.
Replace anodes in their housing and tighten to the required torque.
Oil vapor filter status
Proceed only with engine not running and at low temperature to avoid
any risk of burns.
With choke sensor:
Refer to the indication provided by the sensor.
Without choke sensor:
Check that the filtering item is free from crusting and replace as
directed in the following pages.
Engine lubricant replacement
Proceed only with engine not running and at low temperature to avoid
any risk of burns.
Only with one hand pump:
Place a container to collect the exhaust oil under the hand pump
(3) exit piping (2).
Open the extraction cock by vertically lifting the lever (1) B..
Unscrew the refilling cap, act on the special hand pump (3),
provided for the extraction of the oil, until the oil pan is completely
empty.
Refill oil through the hole provided on the cover. Refer to
REFILLING table for the correct oil type. Tighten the plug.
Using the dip stick (4), that the oil quantity is included between
"Min" and "Max" limits.
Close the cock by lowering back the lever (1) to A position.
Dispose oil observing current regulations in force.