8. Verify that all valves have been returned to the
proper position for normal operation.
9. Open the pressure release valve on the filter, and
make sure it is clean and ready for operation.
10. Turn on the power to the pump. Once all the
air has been evacuated from the filter, close the
pressure release valve.
 

Thepumpmustbeprotectedwhenfreezing
temperaturesareexpected.Allowingthepump
tofreezewillcauseseveredamageandvoidthe
warranty.

Do not use antifreeze solutions in the pool,
spa, or hot tub systems! Antifreezeishighlytoxic
andmaydamagethecirculationsystem.Theonly
exceptiontothisisPropyleneGlycol.Formore
information,seeyourlocalpool/spasupplystoreor
contactaqualifiedswimmingpoolservicecompany.
1. Drain all water from the pump, system equipment,
and piping.
2. Remove the two (2) drain plugs. Store the drain
plugs in a safe location and reinstall them when
the cold weather season is over. Ensure drain plug
o-rings are not misplaced.
3. Keep the motor covered and dry. Do not cover
the pump with plastic, because this will create
condensation that will damage the pump.
 ZodiacPoolSystems,Inc.recommendshaving
aqualifiedservicetechnicianorelectrician
properlydisconnecttheelectricalwiringat
theswitchorjunctionbox.Oncethepoweris
removed,loosenthetwo(2)unionsandstore
thepumpindoors.Forsafety,andtoprevent
entryofcontaminants,reinstallallconduitand
terminalboxcovers.
4. When the system is reopened for operation,
have a qualified technician or electrician make
sure all piping, valves, wiring and equipment
are in accordance with the manufacturers
recommendations. Pay close attention to the filter
and electrical connections.
5. The pump must be primed prior to starting. Refer
to Section 4.1, Start-up.