MNP11M01GB06 May 2007- Rev.4 Page: 17 de 40
Information is transmitted through the RS232C interface with a speed of 1200 or 110
baud.
The RS232C interface is connected to a 400 mm, 4 line, screened cable that has a
standard 9 Pin Sub - D connector.
Printer J-2000 Pin Colour
RXD TXD 2 Black
DTR DTS 4 White
Ground Ground 5 Yellow/Green
Power 12Vdc 9 Green
This address has 5 fields:
“0_24”: Selection of a long or short ticket. For a long ticket program “0” at this
address and “1” for a short ticket.
“1_24” : Selection for communication type. Programming “0”, we will have
communication at a speed of 1200 baud, 8 data bits and 1 stop bit. Programming “1”
we will have communication at a speed of 110 baud, 7 data bits and 1 stop bit.
“2_24” : Selection of the language of the ticket. There are three available tickets:
Value Language
0 Spanish
1 French
2 English
“3_24” : Use this address to program if the compact will test the DTR line of the
printer. Programming “1” the compact will check the DTR line, and programming “0”
the compact will not check the DTR line.
“4_24” : Selection of deleting partial count data after a RS232 output. Programming
“1” will delete count data, and programming “0” will not delete the partial count data.
The selection of this options should be made without having the printer connected.
Tickets can be obtained outside the programming mode, by simply connecting the
printer.
If the address 3_24 is programmed as “1” and the DTR line is switched off, the
compact will wait until the DTR line is switched on. If more than five seconds pass the
transmission will be aborted.
F “__25” :LOADING THE CHANGERS.
This address allows the loading of the tube change tubes. Once the display shows
that this address has been reached, it is enough to insert coins in the selector, it will
only accept those destined to self load until they fill up the tubes.
If some tubes are empty the refund trolley will be placed in a middle position to avoid
the edge of the coins being loaded catching in the groove of the claw causing jams.
This address also shows the value of the coins contained in the tubes.
- Pressing “2” will show the value of the money contained in the tubes.
- Pressing “3” will show the value of the money loaded through this address at the
moment. If we go into and out of this address the value will be cleared.