EasyManua.ls Logo

Jofemar J-2000 - Automatic Unload of Tubes

Jofemar J-2000
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MNP11M01GB06 May 2007- Rev.4 Page: 23 de 40
In the MDB protocol this address is used to program the existence of a recovery
motor. Program “1” if the recovery motor is installed and a “0” if it is not.
“__31” : AUTOMATIC UNLOAD OF TUBES
This address allows to unload the tubes of the compact until a fixed coin level. To set
the number of coins that will last on the compact tubes after doing a automatic unload
you must program the fields “1_31” to “5_31”. The default value to this option is
leaving 10 coins in each tube.
To use this option press “3” on the address indicative to make the display show “----”.
Then press “2” to start the automatic unload.
“__34” OUT OF CHANGE CONDITION
The compact can activate the OUT OF CHANGE condition when the possibility that it
cannot return the remaining credit to the customer is very high. In this condition the
J2000 can inhibit the acceptance of coins of high value and inform the customer (by
means of an illuminated message) that the exact price of the product desired should
be introduced.
0_34: Sets if the compact can sale without exact change.
0: Sale allowed without exact change.
1: Sale allowed only when there is exact change.
1_34: Coins accepted in out of change
0: In out of change are inhibited the coins programmed on address 2_34.
1: Compact only accepts coins routed to tubes.
2_34: Allows that when the out of change condition is activated the coins of greatest
value can be inhibited. The value represents the number of coins inhibited, beginning
with the coin of greatest value. The possible values are from 0 coins inhibited up to 12
coins inhibited. Not is necessary to inhibit the three tokens since they do not make the
compact refund change.
A coin inhibited table for each value programmed is located in the appendix.
“__35” OUT OF CHANGE LEVEL
Use this address to program the minimum level of coins in each one of the tubes to
make the compact go out from out of change.
1_35: Minimum number of coins in the tube 1.
....
5_35: Minimum number of coins in the tube 5.
This address has a default value of 9 coins.
“__38” INDIVIDUAL INHIBITION OF COINS AND TOKENS
This address has four fields and allows the inhibition of the individual acceptance of
coins.
1_38: Inhibition of coins 1 to 4.
2_38: Inhibition of coins 5 to 8.
3_38: Inhibition of coins 9 to 12.
4_38: Inhibition of coins 13 to 16.

Related product manuals