1_30: This address determines which peripheral will be connected to the serial
transmission network. The possible values are:
0: Only the machine controller (VMC).
1: The VMC and the Accountancy Unit (AU).
2: The VMC and the Card Reader (CPC).
3 : VMC, AU and CPC.
4 : VMC and the Note Reader.
5 : VMC, AU and Note Reader.
6 : VMC, Card Reader (CPC) and Note Reader.
7 : VMC, AU, CPC and Note Reader.
2_30: Sales mode:
Allows the choice of the sale mode between one of the following options:
0 : Simple sale. Refunds automatically after carrying out the sale, if there is sufficient
change in the tubes. In event that there is not, the credit is cancelled.
1 : Multiple sale. Consecutive sales are carried out until the credit is used up or the
recovery lever is pressed, in which case it refunds if there is sufficient change in the
tubes and change value is under value of address “1_00”. If there isn’t enough
change, leaves the remainder on display.
2 : Simple mixed sale. Refunds the remaining credit automatically after each sale,
every time it is possible. If it is not the customer can carry out more purchases, until it
is possible to refund the remainder credit.
4 : Simple sale with card revaluation.
5 : Multiple sale with card revaluation.
6 : Simple mixed sale with card revaluation.
3_30: Possibility of escrow
This address allows you to determine the operating of the recovery lever. On the one
hand you can select if the recovery is carried out by means of the traditional
mechanical lever or if a motor and selection button are used for recovery.
On the other hand you can determine if the compact is expected to refund the credit
accumulated every time it is requested or if this refund is allowed only after a
purchase is made.
The possible options are:
0 : Mechanical recovery is always possible.
1 : Mechanical recovery is inhibited until the 1st sale.
2 : Recovery by motor is always possible.
3 : Recovery by motor inhibited until the 1st sale.
The recovery option by motor requires the placing of a component kit on the control
board and the motor in the validator.
WARNING:
If it’s programmed option 0_34 to 1(sale allowed only when there is exact change )
and the field 3_30 is also programmed to 1( mechanical recovery is inhibited until the
1st sale), this last option will not run, allowing the compact to refund before the 1st
sale.