MNP11M01GB06 May 2007- Rev.4 Page: 13 de 40
Self- check:
Each time that you return to sale mode from program mode, or when the compact is
turned on, a self check procedure is started. If an error is detected the display will
show the errors detected during 3 seconds, as a sequence of 1 2 of 3 depending the
problem that is producing this error.
Thousands Hundreds Tens Units
Self - check 1: i
1: At units indicates that a coil in the coin separator is broken. The number of the coil
broken will appear in the address 1_27.
1: At tens a claw of the refund trolley is broken. The number of the tube broken will
appear in the address 2_27.
1: At hundreds a photo-sensor of the coin separator is covered. It’s possible to know
which at the address 3_27.
1: At thousands there is a error in the coin validator. The code of the error will appear
on the address 4_27.
Self - check 2: i
2: At units the motor of the refund trolley is broken or has had a jam. To clear the
error go into the address 5_27.
2: At tens the escrow motor is broken. To clear the error go into address 6_27.
2: At hundreds a coin has gone to a wrong tube. To clear the error go into the address
7_27.
2: At thousands a coil of the safety locks was unplugged. To clear the error go into
the address 8_27.
Self - check 3: i
3: At units shows that prices are unprogrammed.
3: At tens shows that there is an error in tokens values.
3: At hundreds shows that notes are unprogrammed.
3: At units shows that coins in the tubes are unprogrammed.
Self - check 4: i
4: At units shows a error in exterior tubes dispenser.