MNP11M01GB06 May 2007- Rev.4 Page: 19 de 40
Although its possible to do, it is not recommend to allow the compact in normal sale
mode to have a tube with a number of coins less than the security level (3 coins). For
this reason it is not recommended to completely unload any of the tubes.
If a tube it’s totally empty it’s recommended to load to the security level through
address 25.
“__27” : CONSULTING AND RESETTING BREAKDOWNS
This address allows the consulting of
error codes generated by the self check
of the compact. To go to over the 10
fields we use the button “2”. To show the
value of one field we use “3”.
To clear the breakdown we have to press “2” again. The value showed in the field will
be the sum of the errors detected. For example, if the address 3_27 shows a 9, the
photo sensors of tubes 1 and 4 will be covered. The tubes are named as follows:
The error codes showed in each field are:
1_27: Breakdown in the separator coils.
1: Coil 1 broken.
2: Coil 2 broken.
4: Coil 3 broken.
8: Coil 4 broken.
16: Coil 5 broken
This error will be marked when a coin did not reach the tube or when the electrical
connection of the coil is broken.
2_27: Breakdown in the claws of the refund trolley.
1: Coil or claw 1 broken.
2: Coil or claw 2 broken.
4: Coil or claw 3 broken.
8: Coil or claw 4 broken.
16: Coil or claw 5 broken.
This error will also appear when:
- The coin programmed in the address 22 isn’t correct.
- There is an error in the count of coins in the tube.
- There isn’t a good electrical connection to the coil.
- A jam has happened when dispensing coins from this tube.
- The safety lock of this tube is broken.