MNP11M01GB06 May 2007- Rev.4 Page: 20 de 40
3_27: Photo-sensors of the tubes are covered:
1: Sensor of tube 1 is covered.
2: Sensor of tube 2 is covered.
4: Sensor of tube 3 is covered.
8: Sensor of tube 4 is covered.
16: Sensor of tube 5 is covered.
Errors of this address will be self cleared when the sensor is uncovered. Errors in this
address are normally caused by coins jammed at the top of the tube.
4_27: Shows the sum of the error codes in the coin validator. The possible error
codes are:
1: Photo -sensor or T10 coil broken.
2: Synchronism error.
5_27: Shows “1” if the refund motor is broken. If the compact is running under
executive protocol and the refund motor is broken when a refund is being made, the
compact changes to multiple vend to avoid clearing the credit that hasn’t been
refunded. When this error is marked, check the value of the address 2_30.
6_27: Shows “1” when a error is detected in the escrow system.
7_27: Shows the error code caused by a coin that has not followed the intended
routing. The value showed is the sum of the calculated route and the detected route.
The values of the tubes are:
1: For tube 1.
2: For tube 2.
4: For tube 3.
8: For tube 4.
16: For tube 5.
8_27: This field shows the breakdowns in the coils of the safety locks of the refund
trolley. If a safety lock is broken, the compact will also mark as broken the tubes
controlled by the lock.
1: Coil 1 broken-> Breakdown detected in the lock of tubes 1 and 2.
2: Coil 2 broken-> Breakdown detected in the lock of tubes 4 and 5.
3: Coil 1 and 2 broken-> Breakdown detected in the lock of tubes 1,2,4 and 5.
9_27: Shows error detected in the programming options of the compact:
1: Prices are unprogrammed.
2: Tokens are unprogrammed.
4: Notes are unprogrammed.
8: Programming options unprogrammed.
16: Coins to tubes are unprogrammed.
In program mode the address that has caused the deprogramming will be shown
flashing.
A_29: Shows the error in exterior tubes.
1: Error in exterior tube number 1.
2: Error in exterior tube number 2.