QUANTUM™ HD COMPRESSOR CONTROL PANEL
MAINTENANCE
090.040-M (MAR 12)
Page 47
SERVICE - Communications
ACCESSING:
Communications
DESCRIPTION: This screen allows the technician to verify
and troubleshoot serial communications issues.
The following buttons are provided (refer to the Commu-
nications Manual (090.040-CS) for speci c information
about these three tests):
Test Comm1 - Comm2
Test Comm2 - Comm3
Test Comm 3 - Comm1
Redetect I/O Comms - This selection provides
a method to detect all connected Analog and
Digital boards. For additional information about
this screen, refer to 090.040-CS (Communica-
tions Manual).
The following are some of the things that
can occur that would cause an I/O board to
stop communicating with the Quantum™,
and would require that you Redetect I/O
Comms:
A board has been removed, and
power was turned on with the
board removed. You would need to
replace the board, re-power, and
then select [Redetect I/O Com-
ms].
A board has failed in such a way
that it cannot properly communi-
cate with the Quantum™ HD.
A failure with the communications
cable which is plugged into the end
of each board
If any of these things occur, a communica-
tions error shutdown will be issued until this
key is selected. You should always view the
About screen to see what has been detect-
ed.