EasyManuals Logo

Johnson Controls T9100 User Manual

Johnson Controls T9100
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
29
Main Menu Buttons - Humidity
Humidification Settings
The Humidity feature allows the thermostat to
control a humidifier or use your air conditioner
to dehumidify the space.
Humidity
Dehumidification Settings
Run fan when humidifying - OFF
Humidify setpoint
(0%)
Adjust Humidify setpoint. (0% - 60%)
Humidify with heat - OFF
When this step is ON, Humidify will only run with a demand for heat.
Maximum Overcool
This specifies how many degrees the A/C system will run past the cool
setpoint to satisfy a demand for Dehumidification. (0 - 20 degrees F)
Dehumidify setpoint
(99%)
Adjust Dehumidify setpoint. (25% - 99%)
Run A/C to dehumidify - OFF
When this step is ON, the A/C system will be used for Dehumidification.
When this step is ON, the fan will run with a call for Humidification.
IMPORTANT: Aux Output Usage must be set for Hum or
Dehum for these settings to take effect.
See: AUX Output Settings on page 60.
(0˚)
Reheat - OFF
This turns on electric strip heat during an A/C to dehumidify demand to
help maintain desired room temperatures. (Run A/C to dehumidify must
be set to ON and the GAS ELEC Dip Switch must be set to ELEC -
page 77 - to access this feature).
Dehumidify only when cooling - ON
Run dehumidification only when HVAC calls for A/C.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls T9100 and is the answer not in the manual?

Johnson Controls T9100 Specifications

General IconGeneral
BrandJohnson Controls
ModelT9100
CategoryThermostat
LanguageEnglish

Related product manuals