4-21
Main menu
Explanation
Default
Sub-menu1
Sub-menu2
Sub-menu3
4> ALARM
The alarm function when an alarm occurs can be set.
・Alarm sound setting
・LCD color switching (White or Orange).
SYSTEM
An alarm occurs when the system failure occurs.
【ON, OFF】
OFF
SPEED An alarm occurs when the ship speed matches the
set parameters.
【 Over, Under, In range, Out range, OFF 】
OFF
TRIP
An alarm occurs when the trip distance matches the
set parameters.
【 Over, OFF 】
OFF
SPEED LOST
An alarm occurs when computation of the vessel
speed is disabled
【ON, OFF】
OFF
5> SENSOR
Sets a function of signal distributer.
SPEED CORR
Corrects the vessel speed. 【-50.0%~+99.9%】
When + value is set, the displayed value increases.
+0.0%
NMEA1
Sets the output versions of NMEA1 to NMEA4.
【1.5、2.3】
2.3
NMEA2
Sets the output versions of NMEA5 to NMEA8.
【1.5、2.3】
2.3
PULSE1
Sets the distance pulse output rates of LOG1 and
LOG2.
【0~20×100P/NM】
2×100
P/NM
PULSE2
Sets the distance pulse output rates of LOG3 and
LOG4.
【0~20×100P/NM】
2×100
P/NM
PULSE3
Sets the distance pulse output rate of LOG RELAY.
【0~20×100P/NM】
When 0 is set, the output is stopped.
0×100
P/NM
SCALE Adjusts the display scale of the analog vessel
speedometer (optional).
【10~40】
30kn