The screen is shifted to the sewing information display
screen
[E/F process]
[G/H process]
* Others
1) Enable / disable of the sewing pattern can be
changed over by pressing
󱢼
. Every time
󱢼
is pressed, the selected pattern is en-
abled and the valid patterns are displayed on
display portion
N
to
Q
.
Immediately after one of the stitching patterns is
enabled, the numbers of reverse feed stitching
processes (A, B, C and D) are displayed on the
display section
Z
.
2) When switch
󱀁
is pressed, the display
section
A
and
B
changes its display to the num-
ber of stitches for the constant-dimension stitching
process (EF) is displayed.
The number of stitches for the process (EF) can
be set by pressing
󱀄󱢶
.
3) Then, the content shown on display section
󱠄
is changed over to the number of stitches for the
constant-dimension stitching process (GH) by
pressing switch
󱀁
.
The number of stitches (0 to 99) for the process
(GH) can be set by pressing
󱀄󱢶
.
4) When switch
󱀁
is pressed, the content
shown on display section
Z
is changed over to the
numbers of stitches for the reverse feed stitching
processes (A, B, C and D).
N O P Q
A
B
N
󱀄󱢶
C
D
N
󱀄󱢶
– 24 –