ā 106 ā
1 And oH.1, 2 iH.1 Sn.1 On edge of input is detected.
Initialization of output
2 And iL.1 Sn.2
3 StiA Sn.3 C.10 Count of 10 stitches
4 Linh nf.on Lswinh:on (Prohibition of pedal depressing)
5TrM Thread trimming command
6 And iL.24 Sn.6 Stop confirmation
7 DELy oL.1 d.50 Delay :50ms Output 1 : On
8 DELy oL.2 d.50 Delay :50ms Output 2 : On
9 DELy oH.1 d.100 Delay :100ms Output 1 : Off
10 SToP oH.2
Thread trimming command release Output 2 : Off
11 Linh nf.of
Lswinh:off (Replace of Prohibition of pedal depressing)
12 JUMP Sn.1 Repeating aforementioned control.
13 End
14
15
16
17
18
19
20
<Program sample I >
1:opi0, 2:opi1, 3:opi2, 4:opi3, 5:opi4, 6:opi5,
End, DELy, And, or, 7:opi6, 8:opi7, 9:opi0, 10:opi1, 11:opi2,
STiA, Stio, JUMP, 12:opo3, 13:opo4, 14:opo5, 15:opo6, Pn. Program No. d. Delay time Number of stitches : 1 stitch unit
Step SPEd, LiMi, LinH, 1: opo0, 2:opo1, 3:opo2, 4:opo3, 16:opo7, 17:TRMD, 18:WPD, 19:TLSUBD, Sn. Step No. r. Repeat counter Time: 1ms unit
TrM, TinH, UP, HS, 5:opo4, 6:opo5, 7:opo6, 8:opo7, 20:BTD, 21:FLD, 22:BZ, 23:M_ERR, S. Speed C.
Number of stitches
Speed: 10rpm unit
rSW, AnGA, AnGo, 9:BZ 24:S.STATE, 25:HstSW:CP-Panel, nf. on/off A. Angle Angle: 1 degree unit
SToP, bT, FL, rEST 26: LSSW, 27:BTSW, 28:UDET, 29:DDET,
30:UP, 31:DOWN, 32:SET+, 33:SET-
No. Co. command oH. oL. output information iH. iL. input information Parameter
1
Parameter
2
Remarks
<Program sample I >
Optional input 1 is On, automatic thread trimming
is performed after 10 stitches of number of stitches
count, and stop.
After stop, 100 ms of optional output 1 is output.
And, 150 ms is output to optional output 2 after a
lapse of 50 ms after stop.
Input 1
Thread trimming
Stop
Output 1
Output 2
10 stitches
50ms 50ms
100ms
............................................
...........................
............
............
.....
.....