1 And oH.1, oL. 2 iH.1 Sn.1 On edge of input is detected. Output 2 : On
2 And iH.1 Sn.4 d.20 On delay :20ms (Chatter protection)
3 JUMP Sn.2 On waiting
4 LiMi S.200 2000rpm speed limitation (10 rpm unit)
5 And oH.2, oL.1 iH.1 Sn.5 On edge of input is detected. Output 1 : On
6 And iH.1 Sn.8 d.20 On delay :20ms (Chatter protection)
7 JUMP Sn.6 On wating
8 LiMi S.650 Release of speed limitation :6,500 rpm
(10 rpm unit)
9 JUMP Sn.1 Repeating aforementioned control.
10 End
11
12
13
14
15
16
17
18
19
20
<Program sample II >
<Program sample II >
Optional input 1 is On edge, and make speed limi-
tation 2,000 rpm. Release speed limitation after
making On edge of input 1 again.
Make optional output 1 On during limiting speed,
and make output 2 On during release.
....................................
Input 1
6,500 rpm
Speed limitation
2,000 rpm
Output 1
Output 2
....................................
1:opi0, 2:opi1, 3:opi2, 4:opi3, 5:opi4, 6:opi5,
End, DELy, And, or, 7:opi6, 8:opi7, 9:opi0, 10:opi1, 11:opi2,
STiA, Stio, JUMP, 12:opo3, 13:opo4, 14:opo5, 15:opo6, Pn. Program No. d. Delay time Number of stitches : 1 stitch unit
Step SPEd, LiMi, LinH, 1: opo0, 2:opo1, 3:opo2, 4:opo3, 16:opo7, 17:TRMD, 18:WPD, 19:TLSUBD, Sn. Step No. r. Repeat counter Time: 1ms unit
TrM, TinH, UP, HS, 5:opo4, 6:opo5, 7:opo6, 8:opo7, 20:BTD, 21:FLD, 22:BZ, 23:M_ERR, S. Speed C.
Number of stitches
Speed: 10rpm unit
rSW, AnGA, AnGo, 9:BZ 24:S.STATE, 25:HstSW:CP-Panel, nf. on/off A. Angle Angle: 1 degree unit
SToP, bT, FL, rEST 26: LSSW, 27:BTSW, 28:UDET, 29:DDET,
30:UP, 31:DOWN, 32:SET+, 33:SET-
No. Co. command oH. oL. output information iH. iL. input information Parameter