– 15 –
ENGLISH
#
. FOR THE OPERATOR
1. Operating procedure of SC-910N
1) Press ON button
1
of the power switch to turn
ON the power.
(Caution) In case the power indication LED does
not lights up even when turning ON the
power switch,immediately turn OFF the
power and check the voltage.
In addition, in such a case as this, re-
turn ON the power switch when 2 to
3 minutes or more have passed after
turning OFF the power switch.
(When overvoltage is inputted, the
protecting circuit works and re-turning
in the state that the power is not com-
pletely turned OFF is not received.)
Display of power ON
When operation panel (CP-170, and IP-110) is not used
LED of the display of reverse stitching or overlapped stitching at
the front cover of control box lights up. (
A
)
* The power display LED that is built in the machine head
lights up according to the machine head.
When operation panel (CP-170, and IP-110) is used
Power lamp of CP-170 or IP-110 lights up.
Two dots
B
of the number indicating window at the front cover of
control box light up.
(Caution) When the buzzer continues sounding immedi-
ately after turning ON the power, the cord may
not be properly connected or power voltage may
be not proper. Press OFF button
2
of the power
switch to turn OFF the power.
[When operation panel is connected]
[When operation panel is not connected]
A
B
2) When the needle bar is not in UP position, it automatically turns to the UP position.
(Caution) WhenturningONthepowerforthersttime,thereisthecasewherethetimingisslightly
retarded to perform the initialization work. When turning ON the power, the needle bar
moves. Do not put your hands or things under the needle.
3) When depressing front part
3
of the pedal, the
sewing machine rotates at the number of revolu-
tions in accordance with the depressing amount.
When the pedal is returned to the neutral posi-
tion, the sewing machine stops.
4) When lightly depressing back part
4
of the ped-
al, the presser goes up. (PFL type only)
5) When strongly depressing back part
5
of the
pedal, thread trimming is performed.
(Caution) For KFL and PFL types, thread
trimming entering point is different
from each other.
4
3
5
12