EasyManua.ls Logo

Jungheinrich EKS 310 - Page 72

Jungheinrich EKS 310
97 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F 5
0708.GB
p) Replace hydraulic hoses after 6 years' operation
Maintenance intervals
Standard = t WA BC
Hydraulic
System:
6.1 Test operation t
6.2 Check connections and ports for leaks and damage t
6.3 Check hydraulic cylinder for leaks and damage and
make sure it is secure
t
6.4 Check oil level t
6.5 Test the hoses and check for damage t
6.6 Check ventilation and discharge filter on hydraulic
reservoir
t
6.7 Replace ventilation and discharge filter on hydraulic
reservoir
t
6.8 Replace hydraulic oil and filter cartridge t
6.9 Test pressure relief valves t
6.10 Make sure hydraulic hoses are sealed and check for
damage. p)
t
6.11 Test line brake safety device t
Electrical
System:
7.1 Test static charge eliminator t
7.2 Test operation t
7.3 Make sure wire connections are secure and check for
wire damage
t
7.4 Test cable guide operation and check for damage t
7.5 Test operation of warning devices and safety switches. t
7.6 Make sure sensors are fixed, not damaged, clean and
operational
t
7.7 Test operation of controls and displays. t
7.8 Check contactors and relays; if necessary replace worn
parts
t
7.9 Check fuse rating t
Electric
motors:
8.2 Check motor attachment t
Battery: 9.1 Check acid density, acid level and cell voltage t
9.2 Check terminals are securely attached, and apply
grease
t
9.3 Clean battery plug connections, make sure they are
firmly secured
t
9.4 Check battery cables for damage, replace if necessary. t
F 5
0708.GB
p) Replace hydraulic hoses after 6 years' operation
Maintenance intervals
Standard = t WA BC
Hydraulic
System:
6.1 Test operation t
6.2 Check connections and ports for leaks and damage t
6.3 Check hydraulic cylinder for leaks and damage and
make sure it is secure
t
6.4 Check oil level t
6.5 Test the hoses and check for damage t
6.6 Check ventilation and discharge filter on hydraulic
reservoir
t
6.7 Replace ventilation and discharge filter on hydraulic
reservoir
t
6.8 Replace hydraulic oil and filter cartridge t
6.9 Test pressure relief valves t
6.10 Make sure hydraulic hoses are sealed and check for
damage. p)
t
6.11 Test line brake safety device t
Electrical
System:
7.1 Test static charge eliminator t
7.2 Test operation t
7.3 Make sure wire connections are secure and check for
wire damage
t
7.4 Test cable guide operation and check for damage t
7.5 Test operation of warning devices and safety switches. t
7.6 Make sure sensors are fixed, not damaged, clean and
operational
t
7.7 Test operation of controls and displays. t
7.8 Check contactors and relays; if necessary replace worn
parts
t
7.9 Check fuse rating t
Electric
motors:
8.2 Check motor attachment t
Battery: 9.1 Check acid density, acid level and cell voltage t
9.2 Check terminals are securely attached, and apply
grease
t
9.3 Clean battery plug connections, make sure they are
firmly secured
t
9.4 Check battery cables for damage, replace if necessary. t

Table of Contents

Related product manuals