F 5
0708.GB
p) Replace hydraulic hoses after 6 years' operation
Maintenance intervals
Standard = t WA BC
Hydraulic
System:
6.1 Test operation t
6.2 Check connections and ports for leaks and damage t
6.3 Check hydraulic cylinder for leaks and damage and
make sure it is secure
t
6.4 Check oil level t
6.5 Test the hoses and check for damage t
6.6 Check ventilation and discharge filter on hydraulic
reservoir
t
6.7 Replace ventilation and discharge filter on hydraulic
reservoir
t
6.8 Replace hydraulic oil and filter cartridge t
6.9 Test pressure relief valves t
6.10 Make sure hydraulic hoses are sealed and check for
damage. p)
t
6.11 Test line brake safety device t
Electrical
System:
7.1 Test static charge eliminator t
7.2 Test operation t
7.3 Make sure wire connections are secure and check for
wire damage
t
7.4 Test cable guide operation and check for damage t
7.5 Test operation of warning devices and safety switches. t
7.6 Make sure sensors are fixed, not damaged, clean and
operational
t
7.7 Test operation of controls and displays. t
7.8 Check contactors and relays; if necessary replace worn
parts
t
7.9 Check fuse rating t
Electric
motors:
8.2 Check motor attachment t
Battery: 9.1 Check acid density, acid level and cell voltage t
9.2 Check terminals are securely attached, and apply
grease
t
9.3 Clean battery plug connections, make sure they are
firmly secured
t
9.4 Check battery cables for damage, replace if necessary. t
F 5
0708.GB
p) Replace hydraulic hoses after 6 years' operation
Maintenance intervals
Standard = t WA BC
Hydraulic
System:
6.1 Test operation t
6.2 Check connections and ports for leaks and damage t
6.3 Check hydraulic cylinder for leaks and damage and
make sure it is secure
t
6.4 Check oil level t
6.5 Test the hoses and check for damage t
6.6 Check ventilation and discharge filter on hydraulic
reservoir
t
6.7 Replace ventilation and discharge filter on hydraulic
reservoir
t
6.8 Replace hydraulic oil and filter cartridge t
6.9 Test pressure relief valves t
6.10 Make sure hydraulic hoses are sealed and check for
damage. p)
t
6.11 Test line brake safety device t
Electrical
System:
7.1 Test static charge eliminator t
7.2 Test operation t
7.3 Make sure wire connections are secure and check for
wire damage
t
7.4 Test cable guide operation and check for damage t
7.5 Test operation of warning devices and safety switches. t
7.6 Make sure sensors are fixed, not damaged, clean and
operational
t
7.7 Test operation of controls and displays. t
7.8 Check contactors and relays; if necessary replace worn
parts
t
7.9 Check fuse rating t
Electric
motors:
8.2 Check motor attachment t
Battery: 9.1 Check acid density, acid level and cell voltage t
9.2 Check terminals are securely attached, and apply
grease
t
9.3 Clean battery plug connections, make sure they are
firmly secured
t
9.4 Check battery cables for damage, replace if necessary. t

Table of Contents