EasyManua.ls Logo

JVC BR-DV6000 - REMOTE Menu Settings; REMOTE (1;2) Menu Options

JVC BR-DV6000
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
REMOTE Menu screens
The REMOTE Menu consists of the following two screens (1/2 and 2/2).
Item Setting Description
REMOTE SEL
9P
REMOTE SEL
SER
REMOTE SEL
DV
REMOTE SEL
JVC
REMOTE SEL
NET
OFF
ON
OFF
ON
LOC+REM
OFF
ON
LOC+REM
OFF
ON
OFF
ON
LOC+REM
For enabling/disabling the REMOTE1 (9-PIN) terminal when the
REMOTE/LOCAL switch on the front panel is set to REMOTE.
OFF : Control through RS-422A disabled
ON : Control through RS-422A enabled
For enabling/disabling control via the SERIAL REMOTE IN ter-
minal.
OFF : Control disabled regardless of the settings of the
REMOTE/LOCAL switch
ON : Control enabled only when the REMOTE/
LOCALswitch is set to REMOTE.
LOC+REM : Control enabled regardless of the settings of the
REMOTE/LOCAL switch.
For enabling/disabling control via the DV terminal.
OFF : Control disabled regardless of the settings of the
REMOTE/LOCAL switch.
ON : Control enabled only when the REMOTE/
LOCALswitch is set to REMOTE.
LOC+REM : Control enabled regardless of the settings of the
REMOTE/LOCAL switch.
For enabling/disabling the REMOTE 2 (12-PIN) terminal when
the REMOTE/LOCAL switch on the front panel is set to REMOTE.
OFF : Control through the JVC bus disabled
ON : Control through the JVC bus enabled
For enabling/disabling control via the network board SA-DV6000
(sold separately).
OFF : Control disabled regardless of the settings of the
REMOTE/LOCAL switch.
ON : Control enabled only when the REMOTE/
LOCALswitch is set to REMOTE.
LOC+REM : Control enabled regardless of the settings of the
REMOTE/LOCAL switch.
REMOTE (1/2) Menu screen
Memo
When the RS-232C board SA-K46U (sold separately) is installed, the name of this item changes
to REMOTE SEL 232.
Use this setting to enable/disable the control via RS-232C when the REMOTE/LOCAL switch
on the front panel is set to REMOTE.
DV6000U_72-104_Eng.p65e 06/03/03, 11:41 PM75

Table of Contents

Related product manuals