Commissioning Technical Manual
48 04045524 - 08/2016 Kaba access manager 92 32
6.3.5 Installing the registration unit
The actual commissioning of the device is carried out via a registration unit assigned
to it in the partner application. Therefore, at least one registration unit must be in-
stalled and connected to the device before the commissioning of the device.
6.3.6 Commissioning the device with setup medium
After the system has been planned and the setup medium has been detected in the
partner application, the registration units have been connected to the access man-
ager on site, the access manager has been connected to the network (Ethernet) on
site and power supply has been provided, it can be put into operation after a waiting
period of approx. 4 minutes by means of the setup medium as follows:
• Hold the setup medium at a registration unit
For commissioning of the device by means of the setup medium, only a reader with-
out PIN can be used!
• The access manager will produce 2 consecutive acoustic signals. This means that
it has detected the setup medium and begins now to communicate with the
Kaba exivo Internet platform. After registration in the Internet platform, the
green status LED is lit
• The access manager is displayed in the partner application
• The ID of the access manager appears in the partner application in a drop-down
list with all access managers available in the system with the same template type
• Now, the access manager to be used must be assigned to the corresponding
door in the partner application
• The configuration determined in the partner application is loaded now to the ac-
cess manager
• After that, the access manager is ready for use