5.7.5 Inputs
The access manager has 4 inputs IN1 to IN4.
Function of the inputs
The inputs are used for the inquiry of sensors such as door-opener key, door handle
contact, door frame contact, bolt contact, vandal contact, passage control (e.g., turn-
stile, light barrier), etc.
The function of the individual inputs depends on the selected door template.
Principle
The inputs (IN1-IN4) are activated by means of a potential-free contact (switch or re-
lay contact). An open input is recognized as “high” due to the internal pull-up resis-
tor.
5.7.5.1 Line monitoring
The inputs can be designed as follows:
Without line monitoring
With line monitoring (if supported and activated by the terminal software)
Line monitoring allows the terminal software to detect the states short circuit and in-
terruption, in addition to the states active (input closed) and not active (input open)
and report them to the higher-level system.
The current states of the inputs are indicated by light emitting diodes (see chapter
Light emitting diodes [}4.10]).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kaba Access manager 92 32 and is the answer not in the manual?

Kaba Access manager 92 32 Specifications

General IconGeneral
BrandKaba
ModelAccess manager 92 32
CategoryCard Reader
LanguageEnglish

Related product manuals