■ Attached components such as cyclone separators, condensate drains or filters
■ Rain protection covers
➤ Please consult with KAESER if you have questions to the appropriate lifting gear.
Precondition The lifting gear complies with local safety regulations.
No pressure should bear on the sides of the machine cabinet.
Fig. 35 Transport with a crane
1 Lifting gear
2 Slings
1.
NOTICE!
The machine can be damaged by incorrect attachment of the lifting gear!
➤ Do not attach the lifting gear to any of the machine components.
2. Use the lifting gear correctly and lift the machine carefully.
12.5 Disposal
When disposing of a machine, drain out all liquids and remove dirty filters.
Precondition The machine is decommissioned.
1. Completely drain the cooling oil from the machine.
2. Remove used filters and the oil separator cartridge.
3. Hand the machine over to an authorized disposal expert.
➤ Components contaminated with cooling oil must be disposed of in accordance with local
environment protection regulations.
Machines with refrigeration dryers
The sealed refrigerant circuit still contains both refrigerant and oil.
➤ Refrigerant and oil must be drained and disposed of by an authorized body.
12 Decommissioning, Storage and Transport
12.5 Disposal
92
Service Manual Screw Compressor
ASK T SIGMA CONTROL BASIC 9_5717 20 E