ASK 27 ASK 32 ASK 35
Current input [A] 32 37 42
Tab. 30 Mains supply 460V/3/60Hz
2.15 Option W1
Available heat capacity
The quality of the heat transfer medium and its required flow rate depend on the type of heat
exchanger used.
Maximum permissible pressure loss in the cooling air circuit: 0.6 bar
Maximum heat capacity
available*
ASK 27 ASK 32 ASK 35
[kW] 13.0 15.8 17.8
[MJ/h] 47 57 64
[kcal/h] 11188 13598 15319
* With the combination valve set to open at 80 °C.
Tab. 31 Heat capacity (option W1)
2.16 Refrigeration dryers
Model
ASK 27 ASK 32 ASK 35
Model *
* Read off the dryer model from the dryer nameplate and enter it in the table.
Tab. 32 Refrigeration dryer: Model
Compressed air system
ABT 27 ABT 32
Pressure drop [bar]
(referred to 7 bar working
pressure)
0.2 0.2
Maximum permissible
working pressure [bar]
16 16
Tab. 33 Refrigeration dryer: Compressed air system
Refrigerant circuit
The refrigeration dryer contains a refrigerant that is classified by the Kyoto Protocol as a fluorinated
global warming gas.
2 Technical Specifications
2.15 Available heat capacity
14
Service Manual Screw Compressor
ASK T SIGMA CONTROL BASIC 9_5717 20 E