10.7 Air Filter Maintenance
Check that all sealing surfaces match each other. The use of an unsuitable air filter element
can permit dirt to ingress the pressure system and cause damage to the machine.
The air filter element cannot be cleaned.
Material Replacement part
Precondition The power supply disconnecting (isolating) device is switched off,
the disconnect device is locked in the off position,
a check has been made that no voltage is present.
The machine has cooled down.
Fig. 22 Air filter maintenance
1 Snap fastener
2 Air filter element
3 Air filter housing
1. Release the spring clips and remove the element.
2. Clean all parts and sealing surfaces.
3. Insert the new element in the housing.
4. Clip the air filter housing onto the inlet valve.
10.8 Compressor motor maintenance
The drive motor bearings are permanently greased. Re-greasing is not necessary.
Have the motor bearings checked by an authorised KAESER Service.
10 Maintenance
10.7 Air Filter Maintenance
66
Service Manual Screw Compressor
ASK T SIGMA CONTROL BASIC 9_5717 20 E

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASK T series and is the answer not in the manual?

KAESER ASK T series Specifications

General IconGeneral
BrandKAESER
ModelASK T series
CategoryAir Compressor
LanguageEnglish

Related product manuals