EasyManua.ls Logo

KAESER ASK T series - Delivery; Tab. 10 Pressure Relief Valve Activating Pressure (50 Hz); Tab. 11 Pressure Relief Valve Activating Pressure (60 Hz); Tab. 12 Delivery (50 Hz)

KAESER ASK T series
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pressure relief valve activating pressure at 50Hz [bar]
Maximum working over‐
pressure [bar]
ASK 27 ASK 32 ASK 35
8.0 10 10 10
11.0 13 13 13
15.0 16* 16* 16*
* China: 15.9
Tab. 10 Pressure relief valve activating pressure (50Hz)
Pressure relief valve activating pressure at 60 Hz [bar]
Maximum working over‐
pressure [bar]
ASK 27 ASK 32 ASK 35
8.5 10 10 10
11.0 13 13 13
15.0 16 16 16
Tab. 11 Pressure relief valve activating pressure (60Hz)
2.8 Delivery
Delivery [m
3
/min] at 50 Hz mains frequency
Maximum working pres‐
sure [bar]
ASK 27 ASK 32 ASK 35
8.0 2.60 3.15 3.50
11.0 2.17 2.65 2.95
15.0 1.68 2.03 2.35
Tab. 12 Delivery (50 Hz)
Delivery [m
3
/min] at 60 Hz mains frequency
Maximum working pres‐
sure [bar]
ASK 27 ASK 32 ASK 35
8.5 2.60 3.15 3.50
11.0 2.17 2.65 2.95
15.0 1.68 2.03 2.35
Tab. 13 Delivery (60 Hz)
2 Technical Specifications
2.8 Delivery
9_5717 20 E
Service Manual Screw Compressor
ASK T SIGMA CONTROL BASIC
7

Table of Contents

Related product manuals