Installation
6 --- 31
6 Installation
6.1 Safety
Voltage!
There is danger of fatal injury caused by touching electrically live compo-
nents.
Isolate all phases of the main power supply.
(switch off the mains supply disconnecting device)
Ensure that the power supply cannot be switched on again (locked
off).
Check that no voltage is present.
Uncontrolled pressure release!
Serious injury or death can result from loosening or opening components
under pressure.
De---pressurize all pressurized components and enclosures.
Minimum pressure/check valves, pressure relief valves and inlet
valves are powerfully spring---loaded.
Fatal injury may occur from incorrect opening of spring---loaded compo-
nents.
Do not open or dismantle valves.
Installation work may only be carried out by authorised personnel!
All functioning parts are factory set.
Changes may not be made without the permission of the manufacturer.
6.2 Reporting Transport Damage
Check the machine for visible and hidden transport damage.
Inform the carrier and the manufacturer in writing of any damage.
6.3 Install the Compressed Air Connection
Pre---condition: air main completely vented.
Fig. 10 Compressed Air Connection
1 Axial compensator or flexible hose
2 Shut---off valve
DANGER
WARNING
WARNING