Operation
8 --- 41
8.1.3 Switching off
Press the ’LOAD/IDLE’ toggle key (13).
The machine switches to IDLE and the LED (7) flashes.
After running in idle for 20 seconds, press the OFF key (3).
The ’Machine ON’ LED goes out (1).
Switch off and lock out the supply disconnecting device.
8.2 Switching Off in an Emergency and Switching On Again
Fig. 18 Switching off in an emergency
9 EMERGENCYSTOP button
Switching off
Press the ’EMERGENCY STOP’ button (9).
The ’EMERGENCY STOP’ button remains latched in.
The compressor is vented and the machine is prevented from re---starting.
Starting again
Pre---condition: Fault rectified.
Turn the ’EMERGENCY STOP’ button in the direction of the arrow to unlatch it.
Press the ’Reset’ key to delete any existing alarm messages.
Switch on the machine.