De---commissioning, Storage and Transport
12 --- 83
12 Decommissioning, Storage and Transport
12.1 De---commissioning
Decommissioning is necessary when the machine:
will not be needed for some time,
is to be moved to another location,
is no longer needed,
is to be scrapped.
Temporary decommissioning
Pre---condition: The machine can be started at regular intervals.
Run the machine once a week under load for at least 30 minutes to ensure corrosion
protection.
Long---term decommissioning
Pre---condition: Before taking out of service the machine should be run under load for at
least 30 minutes.
Machine switched off and fully vented.
The supply disconnecting device is switched off and locked out.
The machine is cooled down completely.
In water---cooled machines, disconnect the water supply and drain all water from the
machine.
All air and electrical connections are disconnected.
12.2 Packing
Material: Desiccant
Plastic sheeting
Wooden transport crate
Pre---condition: Machine is decommissioned.
Machine is dry and cooled down.
Place desiccant inside the machine cabinet.
Wrap the machine in plastic sheeting.
Transport packaging
A wooden crate is required for overland transport to protect the machine from mechanical
damage.
Consult an authorised KAESER service agent for advice on packaging for sea or air trans-
port.